Electromagnetic compatibility (EMC)
With ISO 17025 accredited services and cutting-edge equipment, our EMC laboratory has a solution to suit your needs.
Tests on vehicles and heavy equipment
- Immunity and emission tests
- Load tests up to 100A per phase
Tests on civil and automotive equipment
- Immunity and emission tests (radiated and conducted)
- Electrical tests
- International recognition (EU, Taiwan, GM/Ford/JLR)
Tests on electrical vehicles
- Tests on electrical vehicles in charging mode
- According to Regulation 10 edition 04 and 05
Our test facilities
- Semi-anechoic chamber for vehicles
- • Immunity, radiated and conducted emissions
- • 21 m x 12 m x 8 m
- • 3 to 200 V/m 100 kHz to 18 GHz
- • QUIET ZONE: 5m diameter at 10m according to CISPR 16-1-4
- • Turntable 9m in diameter (static load = 15 t, dynamic load = 9 t)
- (Semi-)anechoic chamber for vehicles and equipment
- • Immunity, radiated and conducted emissions
- • 7 m x 4.75 m x 4.8 m
- • 3 to 30 V/m (300 mA) 100 kHz to 6 GHz
- Semi-anechoic chamber for equipment
- • Radiated and conducted emissions & immunity
- • 6.35 m x 4 m x 3.07 m
- • 3 to 600 V/m (300 mA) 10 kHz to 18 GHz
- Electromagnetic reverberation chamber
- • 4.8 m x 3.7 m x 3.1 m
- • 3 to 600 V/m 200 MHz to 18 GHz
- Climatic chambers
- • -70 to 200°C, up to 99% RH
Click here to download the scope of accreditation certificate